OWH80Q Series 4CH Fanless DC Power Supply
+ High-Performance Power: 600W/1000W/2000Woutput with 0.05% accuracy.
Provides massive 80V voltage and current up to 20
+ High setting/readback resolution: 10mV/1mA
+ CV/CC priority setting
+ Built-in bleed circuit to ensure no residual high voltage at shutdown
+ 3-inch TFT LCD color screen display with curve output and online 1-minute data logging
+ Full digital control integrated with OVP, OCP, OPPprotection
+ Supports LAN, RS485, RS232 serial communication interfaces, and support SCPI
Four High-Accuracy Channels with Flexible Output Combinations
All four channels can be configured independently and support series/parallel operation. Each channel delivers up to 80 V/20 A, with up to 2000 W total power, 10 mV/1 mA resolution, and voltage setting accuracy of ≤0.05% ± 20 mV.

Fanless Design for Low-Noise Applications
The -F models feature fanless cooling and are available in 600 W and 1000 W versions, making them ideal for R&D labs, automated test systems, and noise-sensitive audio/video production environments.

100-Step LIST Sequencing
Each channel supports independent waveform editing and up to 100 LIST steps. Set voltage, current, and dwell time from the front panel or PC software, and import files via USB to reuse complex test sequences.

Real-Time Waveform and 72-Hour Logging
Displays dynamic voltage and current waveform in real time, combining power supply and oscilloscope functionality. Supports USB screenshot capture and up to 72 hours of local data logging to help capture intermittent anomalies.

Remote Control via PC Software
PC software supports remote monitoring, parameter configuration, LIST sequence editing, and data logging. Centralized management of all four channel outputs improves efficiency in complex testing.

Versatile Interfaces for Easy System Integration
USB Host, USB Device, LAN, RS485, and RS232 interfaces support SCPI commands and connect to computers or automated test systems for remote communication and system integration.

The instrument must be operated continuously for more than 30 minutes at the specified operating temperature to achieve the following specifications
|
Model |
OWH8080Q-2000 |
OWH8040Q-600F |
OWH8020Q-1000F |
|
|
Channel |
4 |
|||
|
Rated output (0℃-40℃) |
Voltage |
0 - 80V |
0 - 80V |
0 - 80V |
|
Current |
0 - 20A |
0 -10A |
0 - 5A |
|
|
Power |
4*500W |
4*150W |
4*250W |
|
|
Input power |
100-240Vac *;45Hz-65Hz |
100V-240Vac;45Hz-65Hz |
||
|
Load regulation (%of output+offset) |
CV |
≤0.05%+20mV |
≤0.03%+20mV |
≤0.03%+20mV |
|
CC |
≤0.1%+30mA |
≤0.05%+30mA |
≤0.05%+30mA |
|
|
Input power regulation (%of output+offset) |
CV |
≤0.05%+20mV |
≤0.03%+20mV |
≤0.05%+20mV |
|
CC |
≤0.1%+30mA |
≤0.05%+30mA |
≤0.05%+30mA |
|
|
Setting resolution |
10mV/1mA |
|||
|
Readback resolution |
10mV/1mA |
|||
|
Setting accuracy |
Voltage |
≤0.05% ± 20mV |
≤0.05% ± 40mV |
≤0.05% ± 40mV |
|
Current |
≤0.1% ± 30mA |
≤0.1% ± 0.1%FS |
≤0.1% ± 0.1%FS |
|
|
Readback accuracy |
Voltage |
≤0.05% ± 20mV |
≤0.05% ± 40mV |
≤0.05% ± 40mV |
|
Current |
≤0.1% ± 30mA |
≤0.1% ± 0.1%FS |
≤0.1% ± 0.1%FS |
|
|
Ripple noise |
Voltage |
≤50mVp-p |
≤100mVp-p |
≤100mVp-p |
|
Current |
≤30mArms |
≤100mArms |
≤120mArms |
|
|
Output temp drift coefficient (0℃-40℃) |
100ppm/℃(Voltage);200ppm/℃(Current) |
|||
|
Readback temp drift |
100ppm/℃(Voltage);200ppm/℃(Current) |
|||
|
Transient response (10%-90% rated load) |
≤5.0ms |
|||
|
Working temperature |
0-40℃ |
|||
|
Display |
USB, LAN, RS485,RS232 |
|||
|
Interface |
4.3-inch TFT LCD screen |
|||
|
Dimension(W*H*Dmm) |
215.0 x 133.0 x 446.2 |
|||
|
Weight (kg) |
Approx. 6kg |
|||
*:Input voltage: 100-120V AC, output power reduced by half.(Input Current ≤10A)
General Accessories
| Name | Order Number |
|---|---|
| Quick Guide | ———— |
| Power Cord | ———— |
| USB Cable | 7ULD10 |










PDF Export
E-mail Us