OC6000 Series Current Probe
+ Maximum peak current: 75 A
+ Bandwidth: up to 120 MHz
+ One-click degauss and zeroing for easy operation
+ Audible and visual overcurrent alarm to prompt switching to the appropriate range
+ Locking mechanism ensures reliable contact between upper and lower magnetic cores
+ Measurement accuracy up to 1%, meeting most testing requirements
+ Dual-range design for measuring different current levels
+ Overcurrent protection to prevent damage from overheating
|
Model |
OC6053 |
OC6123 |
OC6055 |
|
|
Bandwidth(-3dB) |
50MHz |
120MHz |
50MHz |
|
|
Rise time |
≤7ns |
≤2.92ns |
≤7ns |
|
|
Maximum measured current |
30Arms |
30Arms |
50Arms |
|
|
Peak current |
50Apk |
75Apk |
||
|
Range |
5A:1X attenuation |
7.5A:1X attenuation |
||
|
30A:10X attenuation |
50A:10X attenuation |
|||
|
Over current alarm value |
5A:≥5A |
7.5A:≥7.5A |
||
|
30A:≥50A |
50A:≥75A |
|||
|
Current transfer ratio |
5A:1V/A |
7.5A:1V/A |
||
|
30A:0.1V/A |
50A:0.1V/A |
|||
|
Resolution |
5A:1mA |
7.5A:1mA |
||
|
30A:10mA |
50A:10mA |
|||
|
Accuracy (DC,45-66Hz maximum continuous current) |
5A:±1% ±10mA |
7.5A:±1% ±10mA |
||
|
30A:±1% ±100mA |
50A:±1% ±100mA |
|||
|
Delay time-lapse |
Probe host |
14ns |
||
|
BNC(1m) |
5ns |
|||
|
Terminal load requirements |
≥100kΩ |
|||
|
Power supply mode |
DC 12V/2A(Standard adapter) |
|||
|
Maximum voltage to ground(Bare conductor) |
600V CAT Ⅱ 300V CAT Ⅲ |
|||
|
Jaw diameter |
5mm |
|||
|
Cable length |
1m(Current clamp handle to control box) |
|||
|
Coaxial output line length |
1m |
|||
|
Current clamp handle size(L*W*H) |
176*39.5*18mm |
|||



E-mail Us