OC5000 Series Current Probe
+ Bandwidth coverage: 500 kHz to 5 MHz
+ Maximum measurable peak current: up to 100 A
+ Measurement accuracy: up to ±3%, suitable for most testing needs
+ Dual-range design: 0.01 V/A and 0.1 V/A
+ One-click zeroing for easy use, eliminates tedious zeroing adjustments
+Dual power modes: adapter and battery, suitable for indoor and outdoor use
+ Low-battery indicator, overload indicator, and audible alert, plus additional protective features
Electrical performance
|
Model |
OC5010A |
OC5110 |
OC5310 |
OC5510 |
|
Bandwidth(-3dB) |
500kHz |
1MHz |
3MHz |
5MHz |
|
Rise time |
≤700ns |
≤350ns |
≤116ns |
≤70ns |
|
Gear level |
L |
H |
||
|
Current Ranges |
50mA~10A peak |
1A~100A peak |
||
|
Range sensitivity |
0.1V/A |
0.01V/A |
||
|
DC accuracy,typical |
3%±50mA |
500mA~40A peak:4%±50mA; 40A~100A peak:±15%max |
||
|
Phase shift |
DC~65Hz:<1.5° |
DC~65Hz:<1° |
||
|
Working voltage RMS |
CATⅠ 600V CAT Ⅱ 600V CAT Ⅲ 300V |
|||
|
Common mode voltage RMS |
CATⅠ 600V CAT Ⅱ 600V CAT Ⅲ 300V |
|||
|
Power adapters |
Power adapters: DC12V/1A ; alkaline batteries: 9V |
|||
|
Low battery indicator function |
When the battery voltage <6.5V, the battery indicator is red. |
|||
|
Overload indication function |
Measured current exceeds range, buzzer sounds |
|||
|
Current clamp size (L*W*H) |
Approximately 230*33*70mm |
|||
|
Maximum size of the measured conducto |
Calibre approximate 12mm |
|||
|
Length of current clamp output coaxial cable |
Approximately 1.5m |
|||
|
Weights |
Approximately 300g(Battery not included) |
|||
Voltage and current rating table
|
Rating |
Maximum working current(A) |
Maximum working voltage(V) |
Maximum floating(V) |
|
|
H (0.01V/A) |
L (0.1V/A) |
|||
|
DC |
100 A |
10 A |
600 V |
600 V |
|
DC+AC peak |
100 A |
10 A |
600 V |
600 V |
|
AC peak |
100 A |
10 A |
600 V |
600 V |
|
AC peak-peak |
200 A |
20 A |
1200 V |
- |
|
RMS CAT III |
70.7 A |
7.07 A |
300 V |
300 V |
|
RMS CAT II |
70.7 A |
7.07 A |
600 V |
600 V |
|
RMS CAT I |
70.7 A |
7.07 A |
600 V |
600 V |



E-mail Us